Back to Nitro
Nitro
NAC
Network Door Controller

Nitro NAC8000N — Specs & Hong Kong Installation

Four-reader network controller — 2,000 cardholders and up to 64 panels on SecNET.

Best for: Multi-reader floors and multi-controller sites

Product overview

The NAC8000N is Nitro’s published network door controller: four reader inputs, 2,000 cardholders, and up to 64 controllers on one USP SecNET system.

It auto-detects Wiegand 26, 32, 34, 64 and 66-bit readers, so existing EM or smart-card heads can stay if the bit length matches. Door rules on the published spec are anti-passback, auto door open, remote door open and multi-card control.

Swan CCTV uses it where a floor has several card readers and the office wants SecNET plus YTMS Pro, not a face terminal on every door.

Nitro NAC8000N

Key features

  • Four readers on one network panel
  • Keeps working as part of a 64-controller SecNET site
  • Accepts mixed Wiegand bit lengths without a fixed 26-bit-only reader
  • Remote unlock from SecNET
  • Professional supply and installation by Swan CCTV in Hong Kong
  • Configured and tested on-site (not leave-in-box DIY)
  • Documentation and user training included with installation packages

Compatibility

  • USP SecNET and YTMS Pro.
  • Wiegand readers at 26/32/34/64/66 bit, including NR-CRD.
  • Standard maglock or strike, exit button and door contact per reader.

Technical specifications

Readers4 inputs
Controllers per systemUp to 64
Cardholders2,000
WiegandAuto-detect 26 / 32 / 34 / 64 / 66 bit
Door rulesAnti-passback, auto open, remote open, multi-card
SoftwareUSP SecNET and YTMS Pro
BrandNitro
SeriesNAC
CategoryNetwork Door Controller
Local supportSupply, install, program, and after-sales by Swan CCTV (Hong Kong)
Typical useMulti-reader floors and multi-controller sites

Hong Kong / local context

Fits a typical Hong Kong office floor or factory entrance where four doors share one controller and more panels can be added up to 64.

Fire-alarm release of maglocks is still wired at the lock power supply, separate from the NAC logic.

Installation notes

  • Mount the panel in a riser or cupboard with a dedicated 12 V lock supply. Do not power locks from a reader cable.
  • Label each of the four reader channels to a door name in SecNET before the client enrols cards.
  • Test anti-passback only after both in and out readers are online.
Professional installation

Installing NAC8000N in Hong Kong?

We supply, install, and commission Nitro systems with site survey, programming for typical HK doors and windows, and after-sales support.